2015 – COMMERCIAL green and energy plan review requirements
COMMERCIAL
What items MUST be on the plans, or provided along with the plans,
to complete the reviews.
Energy needs:
- Outline of building envelope, with dimensions for perimeter, windows and doors, and skylights.
- Air (Poly) Sealing details
- Size and type of wall, wall framing/furr out
- Roof sections showing EXACTLY how this projects roof WILL be built, not a standard cut out sectional.
- List of insulation materials and their R-values and locations on the envelope
- U-Factor and SHGC of windows and glass doors.
- ASHRAE 55 calculations.
- Mechanical, water heating and appliance specifications.
- Plumbing insulation values and locations
- Duct R-value, duct sealing details and duct locations
- Gasket and insulation details for attic hatches and ladders
- Lighting specifications and schedules. Including switches and controls. For both Interior and Exterior lights.
Green needs:
- Project address
- Owner identification
- Architect/drafter identification
- Contractor identification
- Lot Size
- A/C square footage
- Total roof coverage
- Type of parking
- Building use(s)/Occupancy
- Site Waste Management Plan AND Construction Waste Management Plan
- Indoor Air Quality Plan (for construction)
- Walkways and Bike paths to entrances shown on plans
- Site Hardscape shall have one or more of the following:
- Minimum SRI of .30
- Shaded by structures
- Shaded by trees
- Pervious paving, pavers or aggregate
- Lighting specifications and schedules. Including switches and controls. For both Interior and Exterior lights. All lamps shall contain less than 5 milligrams of mercury and exterior light shall be fully shielded and less than 250 watts.
- Material storage plan (construction materials)
- Post-occupancy recycling area shown on plans. Inside or outside.
- Storage areas for lamps, batteries, electronics, and Janitorial supplies.
- Material selection: a minimum 45% of materials used will be: (shown on plans or on specs)
- Used materials
- Recycled content materials
- Recyclable building materials and components
- Bio- based materials
- Indigenous materials
- ASHRAE 55 calculations.
- Mechanical, water heating and appliance specifications.
- Plumbing insulation values and locations
- Duct R-value, duct sealing details and duct locations